Ving CW-5000AI Industrial Water Chiller for a Single 5W-10W Solid-state Laser Cooling, 0.4HP, AC 1P 220V, 50Hz
  • Ving CW-5000AI Industrial Water Chiller for a Single 5W-10W Solid-state Laser Cooling, 0.4HP, AC 1P 220V, 50Hz
  • Ving CW-5000AI Industrial Water Chiller for a Single 5W-10W Solid-state Laser Cooling, 0.4HP, AC 1P 220V, 50Hz
  • Ving CW-5000AI Industrial Water Chiller for a Single 5W-10W Solid-state Laser Cooling, 0.4HP, AC 1P 220V, 50Hz
  • Ving CW-5000AI Industrial Water Chiller for a Single 5W-10W Solid-state Laser Cooling, 0.4HP, AC 1P 220V, 50Hz

See larger image and other views (with zoom)

Ving CW-5000AI Industrial Water Chiller for a Single 5W-10W Solid-state Laser Cooling, 0.4HP, AC 1P 220V, 50Hz

800W cooling capacity, 100W DC pump, 1 outlet and 1 inlet. The water temperature is able to be adjusted.

 

Item Code:CW-5000AI

  • Unit Price : $ 421.00 - 479.00/set   (Discount Notice)

    Wholesale Price :
    • Quantity (sets) Discount Amount/set
      1. 1 0% $479.00
      2. 2 - 3 7% $445.00
      3. 4 - 8 12% $421.00
    • Need more quantities, please submit a Bulk Order inquiry
  • Quantity: set(s) Total Cost: USD $479.00
  • Shipping Weight: 86.4lb (39.28kg) freightFreight

  •   Save $15 for every $200 you spend

  • Submit your order online to get membership points, a proforma invoice will be sent to you after you submit the order.
    Add to  Cart

Buyer Protection

CW-5000AI Industrial Water Chiller for a Single 5W-10W Solid-state Laser Cooling, 0.4HP, AC 1P 220V, 50Hz
CW-5000AI Industrial Water Chiller for a Single 5W-10W Solid-state Laser Cooling, 0.4HP, AC 1P 220V, 50Hz
Description:

S&A CW-5000 is refrigeration type industrial water chiller of 800W cooling capacity. It’s mainly used to have the heat generated during the laser device working that gone through the refrigerating cycle in compressor refrigeration system and eventually transferred to the air. The water temperature is able to be adjusted. There is 1 water outlet and an inlet, applicable to cool single laser glass tube.S&A industrial water chillers are popular for its 2 temperature control modes as constant temperature and intelligent temperature control. Under intelligent mode, the water temperature is adjusted according to ambient temperature. With that 1 key solution, customers no longer need to worry about the water temperature adjustment of seasonal changes.

Features:
• 800W cooling capacity; use environmental refrigerant;
•  Compact size, long working life and simple operation;
• ±0.3℃ precisely temperature control;
• The intelligent temperature controller has 2 control modes, applicable to different applied occasions;  with various setting and display functions;
• Multiple alarm functions: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;
• Multiple power specifications; CE approval;RoHS approval;
• Optional heater and water filter.



Details:
CW-5000 detail
cw-5000 detail
Temperature controller panel:
(1931) CW-5000AG Water Chiller for Single 120W CO2 Laser Tube Cooling AC details3
Under normal circumstance, the new intelligent temperature controller does not need to adjust the controlling parameters.
It will self-adjust controlling parameters according to room temperature, guaranteeing to meet cooling requirements for machines.
Alarm Function’s Description:
(1931) CW-5000AG Water Chiller for Single 120W CO2 Laser Tube Cooling AC function
Flow alarm and output ports:

In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-5000series chillers possesses an unique low flow alarm protection.

The cooling water circulation loop alarm causes and the work of the state table

 
Normal Flow
 Indicator
Flow Alarm
 Indicator
Buzzer
Output Ports
Hi, H2
Output Ports
H1, H3
Circulating pump works properly ON OFF NOT RING DISCONNECTION BREAKOVER
Blocked cooling water circulation loop OFF ON RING BREAKOVER DISCONNECTION
Alarm of water shortage OFF ON RING BREAKOVER DISCONNECTION
Faulted circulating pump OFF ON RING BREAKOVER DISCONNECTION
Power interruption / / / BREAKOVER DISCONNECTION

Note: The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.

Comparison:

 

CW5200
Cooling Method: Compression refrigeration
Cool for Single 130W / 150W co2 laser Tube
Adopt intelligent controller, it will automatically adjust control parameters according to room temperature changes.
CW5000
Cooling Method: Compression refrigeration
Cool for Single 80W / 100W CO2 Laser Tube
Adopt intelligent controller, it will automatically adjust control parameters according to room temperature changes.
CW3000
Cooling Method: Fan Thermolysis
Cool for Single 60W / 80W CO2 Laser Tube
It’s mainly used on the equipment for heat exchange between the heat and the air environment. The water temperature is related to ambient temperature.

One-stop automatic intelligent temperature control: in different environment, user does not need to change setting due to it will automatically switch to appropriate operating temperature.

CW-5000AG, CW-5000BG, CW-5000DG: applied to cool a single 80W CO2 laser tube (emitting rate higher than 60%)

CW-5000AH, CW-5000BH, CW-5000DH: applied to cool a single 5KW spindle or welding equipment
CW-5000AI, CW-5000BI, CW-5000DI: applied to cool a single 5W-10W solid-state laser

Model CW-5000AG CW-5000BG CW-5000DG CW-5000AH CW-5000BH CW-5000DH CW-5000AI CW-5000BI CW-5000DI
Voltage 220V 220V 110V 220V 220V 110V 220V 220V 110V
Frequency 50Hz 60Hz 60Hz 50Hz 60Hz 60Hz 50Hz 60Hz 60Hz
Current 1.4~2.1A 3.5~5.6A 1~4.8A 3.5~5.6A 1.4~2.1A 3.5~5.6A
Compressor power 0.295KW 0.38KW 0.305KW 0.295KW 0.38KW 0.305KW 0.295KW 0.38KW 0.305KW
0.40HP 0.52HP 0.41HP 0.40HP 0.52HP 0.41HP 0.40HP 0.52HP 0.41HP
Refrigeration capacity 2361Btu/h 2999Btu/h 2866Btu/h 2361Btu/h 2999Btu/h 2866Btu/h 2361Btu/h 2999Btu/h 2866Btu/h
0.692KW 0.879KW 0.84KW 0.692KW 0.879KW 0.84KW 0.692KW 0.879KW 0.84KW
595Kcal/h 756Kcal/h 722Kcal/h 595Kcal/h 756Kcal/h 722Kcal/h 595Kcal/h 756Kcal/h 722Kcal/h
Refrigerant R-134a
Refrigerant charge 300g 320g 280g 300g 320g 280g 300g 320g 280g
Reducer Capillary
Protection Overcurrent protection for compressor, flow alarm, over temperature alarm
Pump power 0.03KW 0.051KW 0.1KW
Inlet and outlet External Φ10mm brass connector Φ10mm speedy connector
Max. lift 10 M 12M 25M
Max. flow 10 L/min 13L/min 16 L/min

 

Fill the water tank with purified water. Connect the water inlet of the water tank to the water outlet of the laser machine and connect the water outlet of the water tank to the water inlet of the laser machine. Connect the signal line of the water tank with that of the laser machine. Please see pictures below.

Industrial cooling machine’s installation is very simple, the new machine for the first time using, you can install it as following steps.

A.Open the package to check if the machine is intact and all the necessary accessories are completed.

B.Open the injection port to feed cooling water.
Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling of carbon steel equipment, the water should be added an appropriate amount of anti - corrosion agentia. Working in cold north area, it’s better to use noncorrosive antifreeze fluid.

C.
According to system conditions, please connect the water inlet and outlet pipe well.

D.
Plug in power, turn on the power switch. (Do not start up without water in the water tank!)
(1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal.
(2) After the first boot, you must immediately check whether the water pipe leaks.
(3) Power switched on, if the water temperature is below the set figure, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters.
(4) As it takes a longer time to start the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently.

E.Check the water level in the water tank.
The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep the water level in the green area, it’s allowed to add adequate water again. Please observe and record the current water level, and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage.

F.
Adjust parameters of temperature controller.
 CW-5000 series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to “Operating status and parameters adjustment.”
CW-5000AG Water Chiller for Single 120W CO2 Laser Tube Cooling usage
CW-5000AG Water Chiller for Single 120W CO2 Laser Tube Cooling usage

Maintenance
Cooling machine used in long term, you should open the machine and clean the dust in order to ensure good heat dissipation.
You can use non – corrosive antifreeze if you are in the northern cold regions. 

Cautions

1. Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded! Although the average operating current of the chiller is small, but the instantaneous operating current could be up to 6 ~ 10amps sometimes (The instantaneous operating current of models of AC110V power supply are possible to be up to 10 ~ 15amps).

2. Please make sure there is a stable and normal voltage for the working chiller! As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 200 ~ 250V (110V model is of 100 ~130V). If you do need a wider operating voltage range, customization is available for us.
 
3. To protect the pump, it’s strictly forbidden to run the chiller without having water in the storage water tank! The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise it’s easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly. Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited!

4. Please be sure that the air inlet and air outlet are in good ventilation! There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet.

5. The filter screen must be regularly cleaned! It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller.


6. Please pay attention to the effect of the condensate water! With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm.

Application:
CW5000-water-chiller-cool-for-Picosecond-Lasers
CW-5000application
CW5000-water-chiller-cool-for-UV-laser-marking-machine

CW5000-water-chiller-cool-for-Uv-solid-laser

CW5000-water-chiller-for-cooling-700W1500W-UV-light-source
s&a chiller for cooling uv lamp applicaiton
CW5000-water-chiller-for-cooling-UV-LED-source
CW-5000 application

Industrial-chiller-CW-5000-for-HF-welding-machine
cw-5000chiller




Quality report


 

   

  • All
  • Guidance
  • Item Description
  • Shipping
  • Payment
  • Other
Ask a question

Select a topic:

Item Description Shipping Payment Other


Content:


Attach files:


(File Format:Jpg,Png,CDR,PSD,Ai,PDF or any other file to describe the product.Maximum Single File Size:2GB.)


Verification code:

Shipping :
We ship to more than 200 countries and 300 ports worldwide!
By Express: 3-5 business days
By Sea: 20-60 business days
How much to ship to
my place?
Payment methods:
Credit Cards we accept:
Credit Cards
Payment Services:
Payment Services

Video Guide:

People Also Like Following Products

Want to be Updated with More Promotions? YES!

E-mail sign up for special offers

Product Tags : A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9

©2006-2016 by Beijing ChinaSigns Information Company Limited All Rights Reserved.

Our local sites:

www.Sign-in-China.com, who belongs to Beijing ChinaSigns Information Co., Ltd. is the biggest online supplier of sign products in the world and specialized in providing One Stop Solution for customers to select AD equipments, AD consuming materials, sign exhibition products, etc.

She is also the authorized overseas service center by China Inkjet Printing Association, for which we have set up overseas branches in 6 foreign countries in order to provide better service for our customers all over the world.

Our products cover all field of the AD and signage and all the products we supply are made in accordance with international quality standards as a result that, at present, we have more than 9,000 products online for sale. Since we implement the centralized purchasing, all the products are quoted with competitive prices. Besides, the product quality and our service are both guaranteed by China Inkjet Printing Association as well.