AC 1P 110V 60Hz CW-5000DH Industrial Water Chiller for a Single 5KW Spindle or Welding Equipment Cooling, 0.41HP
  • AC 1P 110V 60Hz CW-5000DH Industrial Water Chiller for a Single 5KW Spindle or Welding Equipment Cooling, 0.41HP
  • AC 1P 110V 60Hz CW-5000DH Industrial Water Chiller for a Single 5KW Spindle or Welding Equipment Cooling, 0.41HP
  • AC 1P 110V 60Hz CW-5000DH Industrial Water Chiller for a Single 5KW Spindle or Welding Equipment Cooling, 0.41HP
  • AC 1P 110V 60Hz CW-5000DH Industrial Water Chiller for a Single 5KW Spindle or Welding Equipment Cooling, 0.41HP

See larger image and other views (with zoom)

AC 1P 110V 60Hz CW-5000DH Industrial Water Chiller for a Single 5KW Spindle or Welding Equipment Cooling, 0.41HP

800W cooling capacity, 50W DC pump, 1 outlet and 1 inlet. The water temperature is able to be adjusted.

   |   196 Transactions

Item Code:CW-5000DH

  • Unit Price : $ 443.00 - 504.00/set   (Discount Notice)

    Wholesale Price :
    • Quantity (sets) Discount Amount/set
      1. 1 0% $504.00
      2. 2 - 3 7% $468.00
      3. 4 - 8 12% $443.00
    • Need more quantities, please submit a Bulk Order inquiry
  • Quantity: set(s) Total Cost: USD $504.00
  • Shipping Weight: 86.4lb (39.28kg) freightFreight

  • Submit your order online to get membership points, a proforma invoice will be sent to you after you submit the order.
    Add to  Cart

Buyer Protection
CW-5000AK Water Chiller advertisement
It is designed for cooling a single 5KW spindle of the cnc engraving machine.
Cooling capacity is 800W.
Have design patent Certificate, CE and RoHS Certificate.
This Water Chiller has been sold largely to Europe, South America, Asia and other markets.
Economic cooling equipment, easy to install and operate, compact and easily movable

• It is designed for cooling a single 5KW spindle of the cnc engraving machine.
• You can choose different model according to local voltage and frequency.
• Small thermolysis water cooler, energy saving, long working life and simple operation
• With completed water flow and over high temperature alarm functions
• It can control the water temperature, precision is ±0.3℃, which provide stable working conditions for laser devices.
• This series of water chillers adopt intelligent controller, which need not adjust the control parameters under normal circumstances, it will automatically adjust control parameters according to room temperature changes, to meet the cooling requirement.
• Multiple alarm function: compressor time-delay protection, compressor overcurrent protection, water flow alarm and over high / low temperature alarm;
• Specific disconnection alarm securing protection.
• Enclosed water tanks, water used for a long time.
• Equipped with alarm output port, can quickly protect sensitive components.
• High cost performance, low failure rate.
• Multiple power specifications; CE approval; RoHS approval.

CW-5000AK Water Chiller details
Temperature controller panel:
CW-5000AK Water Chiller details
Under normal circumstance, the new intelligent temperature controller does not need to adjust the controlling
parameters. It will self-adjust controlling parameters according to room temperature, guaranteeing to meet cooling requirements for machines.

Alarm Function’s Description:
CW-5000AK Water Chiller alarm function

Flow alarm and output ports
In order to guarantee the equipment will not be damaged while cooling water circulation is out of control, CW-5000series chillers possesses an unique low flow alarm protection.

The cooling water circulation loop alarm causes and the work of the state table

Normal Flow
Flow Alarm
Output Ports
Hi, H2
Output Ports
H1, H3
Circulating pump works properly ON OFF NOT RING DISCONNECTION BREAKOVER
Blocked cooling water circulation loop OFF ON RING BREAKOVER DISCONNECTION
Power interruption / / / BREAKOVER DISCONNECTION

The flow alarm is connected to the normally open relay and normally closed relay contacts, requiring operating current less than 5A, working voltage less than 300V.

CW-5000AK Water Chiller comparison
Our water cooling machine has S & A logo 
on the top of injection port.
                           Fake cooler without the logo.
CW-5000AK Water Chiller comparison
Our water chiller has function of Intelligent temperature control  Fake cooler without this function.
Our water chiller has S & A trademark in this label. This image is only to show the brand, specific parameters will vary depending on the model, please refer to the specifications table parameters prevail. Fake cooler without this trademark.                                                                                                                                                                                                                                  
CW-5000AK Water Chiller comparison
Our water chiller has S & A logo on the outfall                   Fake cooler without this logo
S & A trademark is printed on our water chiller.                                 Fake cooler without this trademark
water chiller usages
Industrial cooling machine’s installation is very simple, the new machine for the first time using, you can install it as following steps.
A.  Open the package to check if the machine is intact and all the necessary accessories are completed.

Open the injection port to feed cooling water.
Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling of carbon steel equipment, the water should be added an appropriate amount of anti - corrosion agentia. Working in cold north area, it’s better to use noncorrosive antifreeze fluid.

According to system conditions, please connect the water inlet and outlet pipe well.

Plug in power, turn on the power switch. (Do not start up without water in the water tank!)
(1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal.
(2) After the first boot, you must immediately check whether the water pipe leaks.
(3) Power switched on, if the water temperature is below the set figure, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters.
(4) As it takes a longer time to start the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently.

E.  Check the water level in the water tank.
The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep the water level in the green area, it’s allowed to add adequate water again. Please observe and record the current water level, and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage.

Adjust parameters of temperature controller.
CW-5000 series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to “Operating status and parameters adjustment.”CW-5000AK Water Chiller using stepsCW-5000AK Water Chiller using steps
Cooling machine used in long term, you should open the machine and clean the dust in order to ensure good heat dissipation.  You can use non – corrosive antifreeze if you are in the northern cold regions.

1. Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded! Although the average operating current of the chiller is small, but the instantaneous operating current could be up to 6 ~ 10amps sometimes (The instantaneous operating current of models of AC110V power supply are possible to be up to 10 ~ 15amps).

2. Please make sure there is a stable and normal voltage for the working chiller! As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 200 ~ 250V (110V model
is of 100 ~130V). If you do need a wider operating voltage range, customization is available for us.

3. To protect the pump, it’s strictly forbidden to run the chiller without having water in the storage water tank! The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise it’s easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly. Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited!

4. Please be sure that the air inlet and air outlet are in good ventilation! There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet.

5. The filter screen must be regularly cleaned! It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller.

6. Please pay attention to the effect of the condensate water! With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm.

CW-5000AK Water Chiller process
Quality Report:
CW-5000AK Water Chiller quality report

Note: The Water Chiller is ordering production, need 3 to 5 days of stock up time.

  • All
  • Guidance
  • Item Description
  • Shipping
  • Payment
  • Other
Ask a question

Select a topic:

Item Description Shipping Payment Other


Attach files:

(File Format:Jpg,Png,CDR,PSD,Ai,PDF or any other file to describe the product.Maximum Single File Size:2GB.)

Verification code:

Shipping :
We ship to more than 200 countries and 300 ports worldwide!
By Express: 3-5 business days
By Sea: 20-60 business days
How much to ship to
my place?
Payment methods:
Credit Cards we accept:
Credit Cards
Payment Services:
Payment Services

Video Guide:

People Also Like Following Products

Want to be Updated with More Promotions? YES!

E-mail sign up for special offers

Product Tags : A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 0 1 2 3 4 5 6 7 8 9

©2006-2016 by Beijing ChinaSigns Information Company Limited All Rights Reserved.

Our local sites:

www.Sign-in-China.com, who belongs to Beijing ChinaSigns Information Co., Ltd. is the biggest online supplier of sign products in the world and specialized in providing One Stop Solution for customers to select AD equipments, AD consuming materials, sign exhibition products, etc.

She is also the authorized overseas service center by China Inkjet Printing Association, for which we have set up overseas branches in 6 foreign countries in order to provide better service for our customers all over the world.

Our products cover all field of the AD and signage and all the products we supply are made in accordance with international quality standards as a result that, at present, we have more than 9,000 products online for sale. Since we implement the centralized purchasing, all the products are quoted with competitive prices. Besides, the product quality and our service are both guaranteed by China Inkjet Printing Association as well.

{literal} {/literal}